{"id":5331,"date":"2011-12-21T12:01:57","date_gmt":"2011-12-21T12:01:57","guid":{"rendered":"https:\/\/medicoweb.com\/main\/trans-valvular-impedance-tvi\/"},"modified":"2020-02-20T09:49:40","modified_gmt":"2020-02-20T08:49:40","slug":"trans-valvular-impedance-tvi","status":"publish","type":"page","link":"https:\/\/medicoweb.com\/main\/en\/trans-valvular-impedance-tvi\/","title":{"rendered":"Trans Valvular Impedance \u2013 TVI"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-507\" title=\"tvi_page\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/tvi_page.jpg\" alt=\"\" width=\"644\" height=\"193\" srcset=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/tvi_page.jpg 644w, https:\/\/medicoweb.com\/main\/wp-content\/uploads\/tvi_page-300x90.jpg 300w\" sizes=\"auto, (max-width: 644px) 100vw, 644px\" \/><\/p>\n<p>The cardiac activity is normally monitored by an implantable stimulation device (pacemaker) through the intracavitary detection of the electric signals associated with atrial and ventricular depolarization (A and R waves, respectively) .<\/p>\n<p>The electric signals, however, provide information limited to atrial and\/or ventricular timing. For an optimal control of the heart \u2013 pacemaker system, the electrical sensing should better be integrated with the assessment of mechanical cardiac activity and related hemodynamic parameters.<br \/>\nThe mechanical activity can be assessed by using specific sensors, or alternatively through electrical impedance measurement, which can be performed by means of the same catheters commonly applied in cardiac stimulation, without any reduction in performance and precision with the progress of time. Indeed, the structural and geometric modifications taking place during the cardiac cycle result in periodic impedance fluctuation, which can represent an index of ventricular contractility and systolic outflow.<\/p>\n<p align=\"justify\">A new option in cardiac impedance measurement is the Trans-Valvular Impedance (TVI) technique.<br \/>\nTVI is derived between right atrium and ventricle in standard dual-chamber implants (DDD or VDD with single-pass lead).<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-4952\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/tvi_signal_ecg_trace.jpg\" alt=\"\" width=\"636\" height=\"343\" srcset=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/tvi_signal_ecg_trace.jpg 636w, https:\/\/medicoweb.com\/main\/wp-content\/uploads\/tvi_signal_ecg_trace-300x162.jpg 300w\" sizes=\"auto, (max-width: 636px) 100vw, 636px\" \/><\/p>\n<p>As shown in the tracings, TVI decreases during the atrial systole and the diastolic passive filling, and increases during the ventricular systole, reaching the maximum peak at the end of the Q-T period (i.e.: at the end of ventricular ejection).<\/p>\n<p align=\"justify\">The increasing clinical experience, including thousands of implants performed in the main International Centers, confirms the correlation between TVI, cardiac mechanics, and corresponding hemodynamic performance.<br \/>\nThis allows innovative important applications, like the ejection surveillance at every paced or sensed cardiac beat, and the regulation of stimulation timing. Furthermore, the Cardiologist can take advantage of TVI indications in the preliminary evaluation of the hemodynamic stability of pacemaker patients.<\/p>\n<p>&nbsp;<\/p>\n<h3>One step beyond in the hemodynamic regulation of cardiac pacing:<\/h3>\n<hr \/>\n<p>&nbsp;<\/p>\n<h3>TVI signal automatic calibration<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-full wp-image-1763\" title=\"calibrazione\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/calibrazione.jpg\" alt=\"\" width=\"644\" height=\"193\" srcset=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/calibrazione.jpg 644w, https:\/\/medicoweb.com\/main\/wp-content\/uploads\/calibrazione-300x90.jpg 300w\" sizes=\"auto, (max-width: 644px) 100vw, 644px\" \/><br \/>\nAutosetting of TVI recording configuration, with immediate availability of TVI-dependent functions.<\/p>\n<h3 style=\"text-align: justify;\">Ejection check after ventricular pacing<\/h3>\n<p style=\"text-align: justify;\">The TVI signal is applied to confirm the actual occurrence of ejection after a ventricular pacing pulse. In the event of missed ejection, the pulse energy is increased to restore effective stimulation.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-full wp-image-2183\" title=\"Ejection check after ventricular pacing\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/verifica_eiezione_dopo_pacing.jpg\" alt=\"\" width=\"644\" height=\"320\" srcset=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/verifica_eiezione_dopo_pacing.jpg 644w, https:\/\/medicoweb.com\/main\/wp-content\/uploads\/verifica_eiezione_dopo_pacing-300x149.jpg 300w\" sizes=\"auto, (max-width: 644px) 100vw, 644px\" \/><br \/>\nIf the expected TVI increase is not recorded after a pacing pulse, failure of ventricular capture is assumed and the pulse energy is increased.<br \/>\nThe pacemaker stores in memory the number of no capture alarms and the trend of pulse parameters.<\/p>\n<h3 style=\"text-align: justify;\">Ejection Check After Ventricular Sensing<\/h3>\n<p style=\"text-align: justify;\">The TVI signal is applied to confirm the actual occurrence of ejection after a ventricular sensing event. In case of missed ejection, the pacing mode is switched over from any ventricular-inhibited to the corresponding ventricular-triggered mode, in order to prevent the risk of false inhibition induced by oversensing.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-full wp-image-2185\" title=\"Ejection Check After Ventricular Sensing\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/verifica_eiezione_dopo_sensing.jpg\" alt=\"\" width=\"644\" height=\"320\" srcset=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/verifica_eiezione_dopo_sensing.jpg 644w, https:\/\/medicoweb.com\/main\/wp-content\/uploads\/verifica_eiezione_dopo_sensing-300x149.jpg 300w\" sizes=\"auto, (max-width: 644px) 100vw, 644px\" \/><br \/>\nIf the expected TVI increase is not recorded after a series of 3 ventricular sensing events, any V-inhibited pacing mode is switched over to the corresponding V-triggered one, in order to ensure safety stimulation.<br \/>\nV-triggered and inhibited pacing are alternated at every beat, so that the programmed pacing mode is re-established as soon as a reliable sensing function is restored.<br \/>\nThe number of no-ejection alarms after ventricular sensing is stored in memory.<\/p>\n<h3>Promotion of intrinsic AV conduction warranted by TVI recording<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-full wp-image-1769\" title=\"algoritmo_minimizzazione\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/algoritmo_minimizzazione.jpg\" alt=\"\" width=\"644\" height=\"320\" srcset=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/algoritmo_minimizzazione.jpg 644w, https:\/\/medicoweb.com\/main\/wp-content\/uploads\/algoritmo_minimizzazione-300x149.jpg 300w\" sizes=\"auto, (max-width: 644px) 100vw, 644px\" \/><br \/>\nTVI-based ejection surveillance enables dual chamber pacing after a single event of false ventricular inhibition.<\/p>\n<p>&nbsp;<\/p>\n<h3>Long-term TVI signal comparison<\/h3>\n<p>Acquired waveform comparison with the one at previous check and the one selected as starting reference.<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3263 size-full\" title=\"confronto_lungo_termine\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/confronto_lungo_termine_eng.png\" alt=\"\" width=\"644\" height=\"457\" srcset=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/confronto_lungo_termine_eng.png 644w, https:\/\/medicoweb.com\/main\/wp-content\/uploads\/confronto_lungo_termine_eng-300x213.png 300w\" sizes=\"auto, (max-width: 644px) 100vw, 644px\" \/><\/p>\n<ul>\n<li>TVI waveform comparison to assess long-term hemodynamic stability<\/li>\n<li>Automatic measurement of basic parameters<\/li>\n<li>Diastolic and systolic TVI trends<\/li>\n<\/ul>\n<p>&#8230;<strong>allow screening patients at risk for heart failure<\/strong><\/p>\n<p>&nbsp;<\/p>\n<h3>Full papers in details:<\/h3>\n<hr \/>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" title=\"Articoli scientifici in dettaglio\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/file3.png\" alt=\"\" width=\"32\" height=\"32\" \/><strong>Acute effects of right ventricular pacing on cardiac haemodynamics and transvalvular impedance.<\/strong><\/p>\n<h5>Taborsky M, Fedorco M, Skala T, Kocianova E, Pastucha D, Richter D, Petrkova J, Di Gregorio F, Barbetta A, Vaclavik J<\/h5>\n<p>Biomedical Papers (2013) 157, in press.<br \/>\n<img loading=\"lazy\" decoding=\"async\" title=\"link\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/link.png\" alt=\"\" width=\"16\" height=\"16\" \/>Pre-print Link: <a href=\"http:\/\/dx.doi.org\/10.5507\/bp.2013.009\" target=\"_blank\" rel=\"noopener noreferrer\">click here &gt;&gt;<\/a><br \/>\n<img loading=\"lazy\" decoding=\"async\" title=\"Pubblicazioni\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/file3.png\" alt=\"\" width=\"32\" height=\"32\" \/><strong>Left ventricular mechanical activity detected by impedance recording<\/strong><\/p>\n<h5>Taborsky M, Kupec J, Vopalka R, Barbetta A, Di Gregorio F<\/h5>\n<p>Europace (2010) 12, 534\u2013539<br \/>\n<img loading=\"lazy\" decoding=\"async\" title=\"link\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/link.png\" alt=\"\" width=\"16\" height=\"16\" \/>Link Full paper: <a href=\"http:\/\/www.ncbi.nlm.nih.gov\/pmc\/articles\/PMC2845509\/pdf\/euq052.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">click here &gt;&gt;<\/a><\/p>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" title=\"Full papers in details\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/file3.png\" alt=\"\" width=\"32\" height=\"32\" \/> <strong>Rate-responsive pacing regulated by cardiac haemodynamics<\/strong><\/p>\n<h5>Gasparini G, Curnis A, Gulizia M, Occhetta E, Corrado A, Bontempi L, Mascioli G, Francese GM, Bortnik M, Magnani A, Di Gregorio F, Barbetta A, Raviele A<\/h5>\n<p>Europace (2005) 7, 234\u2013241<br \/>\n<img loading=\"lazy\" decoding=\"async\" title=\"link\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/link.png\" alt=\"\" width=\"16\" height=\"16\" \/>Link Full paper: <a href=\"http:\/\/europace.oxfordjournals.org\/content\/7\/3\/234.full.pdf+html\" target=\"_blank\" rel=\"noopener noreferrer\">click here &gt;&gt;<\/a><\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/tvi_pdf2.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><img loading=\"lazy\" decoding=\"async\" title=\"tvi_pdf_2\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/tvi_pdf_2.jpg\" alt=\"\" width=\"200\" height=\"142\" \/><\/a> <a href=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/tvi_pdf1.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><img loading=\"lazy\" decoding=\"async\" title=\"tvi_pdf_1\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/tvi_pdf_1.jpg\" alt=\"\" width=\"200\" height=\"142\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<p align=\"center\"><a href=\"#top\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/torna_su.png\" alt=\"\" width=\"28\" height=\"28\" \/> Return to top<\/a><\/p>\n<p>&nbsp;<\/p>\n<hr \/>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span style=\"text-align: center; font-size: 16px;\"> <a title=\"Products\" href=\"https:\/\/medicoweb.com\/main\/en\/products\"><strong>Products<\/strong><\/a> | <a title=\"Technology\" href=\"https:\/\/medicoweb.com\/main\/en\/technology\"><strong>Technology<\/strong><\/a> | <a title=\"Support\" href=\"https:\/\/medicoweb.com\/main\/en\/support\"><strong>Support<\/strong><\/a> | <a title=\"Contacts\" href=\"https:\/\/medicoweb.com\/main\/en\/contacts\"><strong>Contacts<\/strong><\/a><\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The cardiac activity is normally monitored by an implantable stimulation device (pacemaker) through the intracavitary detection of the electric signals associated with atrial and ventricular depolarization (A and R waves, respectively) . The electric signals, however, provide information limited to&hellip; <\/p>\n","protected":false},"author":1,"featured_media":5332,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-5331","page","type-page","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Trans Valvular Impedance \u2013 TVI - MEDICO S.R.L.<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/medicoweb.com\/main\/en\/trans-valvular-impedance-tvi\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Trans Valvular Impedance \u2013 TVI - MEDICO S.R.L.\" \/>\n<meta property=\"og:description\" content=\"The cardiac activity is normally monitored by an implantable stimulation device (pacemaker) through the intracavitary detection of the electric signals associated with atrial and ventricular depolarization (A and R waves, respectively) . The electric signals, however, provide information limited to&hellip;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/medicoweb.com\/main\/en\/trans-valvular-impedance-tvi\/\" \/>\n<meta property=\"og:site_name\" content=\"MEDICO S.R.L.\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/MedicoSpa\/\" \/>\n<meta property=\"article:modified_time\" content=\"2020-02-20T08:49:40+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/tvi_evidenza2.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"222\" \/>\n\t<meta property=\"og:image:height\" content=\"160\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/medicoweb.com\/main\/en\/trans-valvular-impedance-tvi\/\",\"url\":\"https:\/\/medicoweb.com\/main\/en\/trans-valvular-impedance-tvi\/\",\"name\":\"Trans Valvular Impedance \u2013 TVI - MEDICO S.R.L.\",\"isPartOf\":{\"@id\":\"https:\/\/medicoweb.com\/main\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/medicoweb.com\/main\/en\/trans-valvular-impedance-tvi\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/medicoweb.com\/main\/en\/trans-valvular-impedance-tvi\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/tvi_evidenza2.jpg\",\"datePublished\":\"2011-12-21T12:01:57+00:00\",\"dateModified\":\"2020-02-20T08:49:40+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/medicoweb.com\/main\/en\/trans-valvular-impedance-tvi\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/medicoweb.com\/main\/en\/trans-valvular-impedance-tvi\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/medicoweb.com\/main\/en\/trans-valvular-impedance-tvi\/#primaryimage\",\"url\":\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/tvi_evidenza2.jpg\",\"contentUrl\":\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/tvi_evidenza2.jpg\",\"width\":222,\"height\":160},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/medicoweb.com\/main\/en\/trans-valvular-impedance-tvi\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/medicoweb.com\/main\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Trans Valvular Impedance \u2013 TVI\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/medicoweb.com\/main\/en\/#website\",\"url\":\"https:\/\/medicoweb.com\/main\/en\/\",\"name\":\"MEDICO S.p.A.\",\"description\":\"Italian Design For Life\",\"publisher\":{\"@id\":\"https:\/\/medicoweb.com\/main\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/medicoweb.com\/main\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/medicoweb.com\/main\/en\/#organization\",\"name\":\"MEDICO S.p.A.\",\"url\":\"https:\/\/medicoweb.com\/main\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/medicoweb.com\/main\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/logo_medico2016-1.png\",\"contentUrl\":\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/logo_medico2016-1.png\",\"width\":350,\"height\":84,\"caption\":\"MEDICO S.p.A.\"},\"image\":{\"@id\":\"https:\/\/medicoweb.com\/main\/en\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/MedicoSpa\/\",\"https:\/\/it.linkedin.com\/company\/medico-s.p.a.\",\"https:\/\/www.youtube.com\/channel\/UCobmQUF5q8SwwMSZ00fA65g\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Trans Valvular Impedance \u2013 TVI - MEDICO S.R.L.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/medicoweb.com\/main\/en\/trans-valvular-impedance-tvi\/","og_locale":"en_US","og_type":"article","og_title":"Trans Valvular Impedance \u2013 TVI - MEDICO S.R.L.","og_description":"The cardiac activity is normally monitored by an implantable stimulation device (pacemaker) through the intracavitary detection of the electric signals associated with atrial and ventricular depolarization (A and R waves, respectively) . The electric signals, however, provide information limited to&hellip;","og_url":"https:\/\/medicoweb.com\/main\/en\/trans-valvular-impedance-tvi\/","og_site_name":"MEDICO S.R.L.","article_publisher":"https:\/\/www.facebook.com\/MedicoSpa\/","article_modified_time":"2020-02-20T08:49:40+00:00","og_image":[{"width":222,"height":160,"url":"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/tvi_evidenza2.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/medicoweb.com\/main\/en\/trans-valvular-impedance-tvi\/","url":"https:\/\/medicoweb.com\/main\/en\/trans-valvular-impedance-tvi\/","name":"Trans Valvular Impedance \u2013 TVI - MEDICO S.R.L.","isPartOf":{"@id":"https:\/\/medicoweb.com\/main\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/medicoweb.com\/main\/en\/trans-valvular-impedance-tvi\/#primaryimage"},"image":{"@id":"https:\/\/medicoweb.com\/main\/en\/trans-valvular-impedance-tvi\/#primaryimage"},"thumbnailUrl":"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/tvi_evidenza2.jpg","datePublished":"2011-12-21T12:01:57+00:00","dateModified":"2020-02-20T08:49:40+00:00","breadcrumb":{"@id":"https:\/\/medicoweb.com\/main\/en\/trans-valvular-impedance-tvi\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/medicoweb.com\/main\/en\/trans-valvular-impedance-tvi\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/medicoweb.com\/main\/en\/trans-valvular-impedance-tvi\/#primaryimage","url":"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/tvi_evidenza2.jpg","contentUrl":"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/tvi_evidenza2.jpg","width":222,"height":160},{"@type":"BreadcrumbList","@id":"https:\/\/medicoweb.com\/main\/en\/trans-valvular-impedance-tvi\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/medicoweb.com\/main\/en\/"},{"@type":"ListItem","position":2,"name":"Trans Valvular Impedance \u2013 TVI"}]},{"@type":"WebSite","@id":"https:\/\/medicoweb.com\/main\/en\/#website","url":"https:\/\/medicoweb.com\/main\/en\/","name":"MEDICO S.p.A.","description":"Italian Design For Life","publisher":{"@id":"https:\/\/medicoweb.com\/main\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/medicoweb.com\/main\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/medicoweb.com\/main\/en\/#organization","name":"MEDICO S.p.A.","url":"https:\/\/medicoweb.com\/main\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/medicoweb.com\/main\/en\/#\/schema\/logo\/image\/","url":"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/logo_medico2016-1.png","contentUrl":"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/logo_medico2016-1.png","width":350,"height":84,"caption":"MEDICO S.p.A."},"image":{"@id":"https:\/\/medicoweb.com\/main\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/MedicoSpa\/","https:\/\/it.linkedin.com\/company\/medico-s.p.a.","https:\/\/www.youtube.com\/channel\/UCobmQUF5q8SwwMSZ00fA65g"]}]}},"_links":{"self":[{"href":"https:\/\/medicoweb.com\/main\/en\/wp-json\/wp\/v2\/pages\/5331","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/medicoweb.com\/main\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/medicoweb.com\/main\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/medicoweb.com\/main\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/medicoweb.com\/main\/en\/wp-json\/wp\/v2\/comments?post=5331"}],"version-history":[{"count":1,"href":"https:\/\/medicoweb.com\/main\/en\/wp-json\/wp\/v2\/pages\/5331\/revisions"}],"predecessor-version":[{"id":6604,"href":"https:\/\/medicoweb.com\/main\/en\/wp-json\/wp\/v2\/pages\/5331\/revisions\/6604"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/medicoweb.com\/main\/en\/wp-json\/wp\/v2\/media\/5332"}],"wp:attachment":[{"href":"https:\/\/medicoweb.com\/main\/en\/wp-json\/wp\/v2\/media?parent=5331"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}