{"id":5433,"date":"2019-12-02T16:36:09","date_gmt":"2019-12-02T15:36:09","guid":{"rendered":"https:\/\/medicoweb.com\/main\/iris-dr-dddr-iris-d-ddd-iris-vdr-vddr\/"},"modified":"2020-02-20T09:35:22","modified_gmt":"2020-02-20T08:35:22","slug":"iris-dr-dddr-iris-d-ddd-iris-vdr-vddr","status":"publish","type":"page","link":"https:\/\/medicoweb.com\/main\/en\/iris-dr-dddr-iris-d-ddd-iris-vdr-vddr\/","title":{"rendered":"Iris DR (DDDR) \u2013 Iris D (DDD) \u2013 Iris VDR (VDDR)"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-4457 size-full alignleft\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/pm_iris_dr_d_vdr.jpg\" alt=\"\" width=\"230\" height=\"180\" \/><\/p>\n<h6 style=\"text-align: right;\">Iris DR (DDDR) <a><br \/>\n<\/a><a href=\"https:\/\/medicoweb.com\/main\/en\/legenda\/\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" title=\"ELETTROGRAMMA INTRACAVITARIO INTEGRATO \/ INTEGRATED INTRACARDIAC ELECTROGRAM\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/iecg_icona.png\" alt=\"\" width=\"45\" height=\"28\" \/><img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" title=\"IMPEDENZA TRANS VALVOLARE \/ TRANS VALVULAR IMPEDANCE\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/tvi_icona.png\" alt=\"\" width=\"45\" height=\"28\" \/><img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" title=\"STIMOLAZIONE DDD \/ DDD STIMULATION\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/ddd_icona.png\" alt=\"\" width=\"45\" height=\"28\" \/><img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" title=\"TECNOLOGIA A MICROPROCESSORE \/ PROCESSOR TECHNOLOGY\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/processore_icona.png\" alt=\"\" width=\"45\" height=\"28\" \/><img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" title=\"SENSORE ACCELEROMETRICO \/ ACCELEROMETRIC SENSOR\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/sensore_accelerometrico_icona.png\" alt=\"\" width=\"45\" height=\"28\" \/><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-4449\" title=\"CONTROLLO REMOTO \/ REMOTE CONTROL\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/ermes_deo_icona.png\" alt=\"\" width=\"45\" height=\"28\" \/><\/a><\/h6>\n<h6 style=\"text-align: right;\">Iris D (DDD) <a><br \/>\n<\/a><a href=\"https:\/\/medicoweb.com\/main\/en\/legenda\/\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" title=\"ELETTROGRAMMA INTRACAVITARIO INTEGRATO \/ INTEGRATED INTRACARDIAC ELECTROGRAM\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/iecg_icona.png\" alt=\"\" width=\"45\" height=\"28\" \/><img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" title=\"IMPEDENZA TRANS VALVOLARE \/ TRANS VALVULAR IMPEDANCE\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/tvi_icona.png\" alt=\"\" width=\"45\" height=\"28\" \/><img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" title=\"STIMOLAZIONE DDD \/ DDD STIMULATION\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/ddd_icona.png\" alt=\"\" width=\"45\" height=\"28\" \/><img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" title=\"TECNOLOGIA A MICROPROCESSORE \/ PROCESSOR TECHNOLOGY\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/processore_icona.png\" alt=\"\" width=\"45\" height=\"28\" \/><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-4449\" title=\"CONTROLLO REMOTO \/ REMOTE CONTROL\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/ermes_deo_icona.png\" alt=\"\" width=\"45\" height=\"28\" \/><\/a><\/h6>\n<h6 style=\"text-align: right;\">Iris VDR (VDDR) <a><br \/>\n<\/a><a href=\"https:\/\/medicoweb.com\/main\/en\/legenda\/\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" title=\"ELETTROGRAMMA INTRACAVITARIO INTEGRATO \/ INTEGRATED INTRACARDIAC ELECTROGRAM\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/iecg_icona.png\" alt=\"\" width=\"45\" height=\"28\" \/><img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" title=\"IMPEDENZA TRANS VALVOLARE \/ TRANS VALVULAR IMPEDANCE\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/tvi_icona.png\" alt=\"\" width=\"45\" height=\"28\" \/><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1379 size-full\" title=\"STIMOLAZIONE VDD \/ VDD STIMULATION\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/vdd_icona.png\" alt=\"\" width=\"45\" height=\"28\" \/><img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" title=\"TECNOLOGIA A MICROPROCESSORE \/ PROCESSOR TECHNOLOGY\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/processore_icona.png\" alt=\"\" width=\"45\" height=\"28\" \/><img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" title=\"SENSORE ACCELEROMETRICO \/ ACCELEROMETRIC SENSOR\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/sensore_accelerometrico_icona.png\" alt=\"\" width=\"45\" height=\"28\" \/><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-4449\" title=\"CONTROLLO REMOTO \/ REMOTE CONTROL\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/ermes_deo_icona.png\" alt=\"\" width=\"45\" height=\"28\" \/><\/a><\/h6>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h4><span style=\"color: #6a7075;\">Advanced dual-chamber pacingwith the support of remote control<\/span><\/h4>\n<hr \/>\n<h6>Learn more about:<\/h6>\n<p><span style=\"color: #6a7075;\"><strong><a href=\"https:\/\/medicoweb.com\/main\/en\/mobile-remote-monitoring\/\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-4449\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/ermes_deo_icona.png\" width=\"45\" height=\"28\" \/>Mobile remote monitoring<\/a>\u00a0 | <a href=\"https:\/\/medicoweb.com\/main\/en\/single-lead-vdd-pacing\/\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-4935 size-full\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/pacing_vdd_icona.png\" alt=\"\" width=\"45\" height=\"28\" \/>Single Lead VDD Pacing<\/a><\/strong><br \/>\n<\/span><\/p>\n<hr \/>\n<h3>Diagnostic evaluation of tachycardia episodes based on an innovative electrogram ( iECG )<\/h3>\n<p>The iECG completes the set of electrograms recorded in the IRIS family: the band-pass filtered atrial and ventricular EGMs (supporting the pacemaker sensing function) and the corresponding wide-band EGMs, which allow a first step evaluation of signal morphology and duration. The iECG further improves this feature, providing a tracing similar to a surface ECG lead, with better visualization of the atrial activity.<br \/>\nIt is automatically recorded in the event of tachycardia (optionally complemented by the TVI tracing) to discriminate ventricular and supraventricular tachyarrhythmias, haemodynamically tolerated or not.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-3288 size-full\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/iecg_svt_eng.jpg\" alt=\"\" width=\"644\" height=\"193\" srcset=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/iecg_svt_eng.jpg 644w, https:\/\/medicoweb.com\/main\/wp-content\/uploads\/iecg_svt_eng-300x90.jpg 300w\" sizes=\"auto, (max-width: 644px) 100vw, 644px\" \/><\/p>\n<p>The iECG ventricular complex morphology is unchanged in SVTs. TVI fluctuation shows reduced amplitude, but is regularly present at every beat.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-3290 size-full\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/iecg_vt_eng.jpg\" alt=\"\" width=\"644\" height=\"193\" srcset=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/iecg_vt_eng.jpg 644w, https:\/\/medicoweb.com\/main\/wp-content\/uploads\/iecg_vt_eng-300x90.jpg 300w\" sizes=\"auto, (max-width: 644px) 100vw, 644px\" \/><\/p>\n<p>The iECG ventricular complex morphology is radically changed in VTs. The example shows a non-tolerated, spontaneously terminated VT. TVI fluctuation is abolished in the absence of ejection and is detected again as soon as sinus rhythm is reestablished.<\/p>\n<hr \/>\n<h3>Ventricular pacing reduction (VPR) with full respect of the haemodynamic constraints<\/h3>\n<p>The pacemakers of the IRIS family are designed to keep the incidence of ventricular pacing at the lowest possible limit still compatible with the haemodynamic efficiency.<br \/>\nThe stimulation could be avoided also on 2nd degree blocks which maintain the conduction ratio within the programmed limit value.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-3268 size-full\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/pr_consentito_eng.jpg\" alt=\"\" width=\"644\" height=\"474\" srcset=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/pr_consentito_eng.jpg 644w, https:\/\/medicoweb.com\/main\/wp-content\/uploads\/pr_consentito_eng-300x221.jpg 300w\" sizes=\"auto, (max-width: 644px) 100vw, 644px\" \/><\/p>\n<p>The upper limit of the accepted PR is automatically adjusted to the cardiac rate to prevent atrial systole against closed valves.<\/p>\n<hr \/>\n<h3>Haemodynamic surveillance and monitoring of ventricular mechanics by Transvalvular Impedance assessment (TVI)<\/h3>\n<p>In the IRIS family, the electrodes used for current injection and related voltage measurement are set independently.<br \/>\nThis way, ventricular motility can be assessed in different areas, to improve the characterization of ventricular mechanics and extend the diagnostic power of TVI evaluation.<br \/>\nIn the absence of external programming at 3 months from implantation, the system automatically selects the TVI configuration providing the most suitable signal.<br \/>\nIn the event of a tachycardia, the TVI tracing can compared with the basal signal, to gain information on the haemodynamic impact of the arrhythmia.<br \/>\nA TVI waveform change in the long term is a useful sign to select patients where a check of the haemodynamic function with conventional methods is advisable.<\/p>\n<hr \/>\n<h3>Autoregulation of atrial and ventricular sensitivity<\/h3>\n<p>Atrial and ventricular sensitivity is automatically adjusted to the intrinsic signal amplitude.<br \/>\nThe algorithm has been studied to provide a safety margin of at least 3X.<br \/>\nThe atrial sensitivity is programmable up to 0.08 mV, thus making the device compatible with the pacing VDD single lead.<\/p>\n<hr \/>\n<h3>Quick and intuitive follow-up checks<\/h3>\n<ul>\n<li>Quick and safe telemetric communication in device programming, as well as in downloading diagnostic data and recorded tracings.<\/li>\n<li>All enabled functions keep on working during the follow-up checks, to allow immediate verification of set-up matching with the clinical needs.<\/li>\n<li>Daily updated battery and leads measurements.<\/li>\n<li>Trends of stimulation energy and amplitude of sensing signals.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<hr \/>\n<h3>Remote control by means of Ermes communication tool<\/h3>\n<p>Medico mobile control keeps patient and physician in touch by:<\/p>\n<ul>\n<li>Performing fast or complete follow-up checks anywhere and anytime.<\/li>\n<li>Detecting possible technical or clinical alerts.<\/li>\n<li>Creating an appropriate report, including iECG and TVI tracings in tachycardia.<\/li>\n<li>Forwarding the report to the specified address.<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-4446 size-full\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/controllo_remoto_ermes_en.jpg\" alt=\"\" width=\"1000\" height=\"441\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<hr \/>\n<p align=\"left\"><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-4629 alignleft\" src=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/icona_supporto.png\" alt=\"\" width=\"45\" height=\"45\" \/><span style=\"color: #0575d2;\"><span style=\"font-size: 10pt;\"><em>For more information or to get technical support on our products please <\/em><\/span><a title=\"Contatti\" href=\"https:\/\/medicoweb.com\/main\/en\/contacts\"><span style=\"font-size: 10pt;\"><strong>CONTACT US<\/strong> &gt;&gt;<\/span><\/a><\/span><\/p>\n<p>&nbsp;<\/p>\n<hr \/>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span style=\"text-align: center; font-size: 16px;\"> <a title=\"Products\" href=\"https:\/\/medicoweb.com\/main\/en\/products\"><strong>Products<\/strong><\/a> | <a title=\"Technology\" href=\"https:\/\/medicoweb.com\/main\/en\/technology\"><strong>Technology<\/strong><\/a> | <a title=\"Support\" href=\"https:\/\/medicoweb.com\/main\/en\/support\"><strong>Support<\/strong><\/a> | <a title=\"Contacts\" href=\"https:\/\/medicoweb.com\/main\/en\/contacts\"><strong>Contacts<\/strong><\/a><\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Iris DR (DDDR) Iris D (DDD) Iris VDR (VDDR) &nbsp; &nbsp; Advanced dual-chamber pacingwith the support of remote control Learn more about: Mobile remote monitoring\u00a0 | Single Lead VDD Pacing Diagnostic evaluation of tachycardia episodes based on an innovative electrogram&hellip; <\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-5433","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Iris DR (DDDR) \u2013 Iris D (DDD) \u2013 Iris VDR (VDDR) - MEDICO S.R.L.<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/medicoweb.com\/main\/en\/iris-dr-dddr-iris-d-ddd-iris-vdr-vddr\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Iris DR (DDDR) \u2013 Iris D (DDD) \u2013 Iris VDR (VDDR) - MEDICO S.R.L.\" \/>\n<meta property=\"og:description\" content=\"Iris DR (DDDR) Iris D (DDD) Iris VDR (VDDR) &nbsp; &nbsp; Advanced dual-chamber pacingwith the support of remote control Learn more about: Mobile remote monitoring\u00a0 | Single Lead VDD Pacing Diagnostic evaluation of tachycardia episodes based on an innovative electrogram&hellip;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/medicoweb.com\/main\/en\/iris-dr-dddr-iris-d-ddd-iris-vdr-vddr\/\" \/>\n<meta property=\"og:site_name\" content=\"MEDICO S.R.L.\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/MedicoSpa\/\" \/>\n<meta property=\"article:modified_time\" content=\"2020-02-20T08:35:22+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/pm_iris_dr_d_vdr.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/medicoweb.com\/main\/en\/iris-dr-dddr-iris-d-ddd-iris-vdr-vddr\/\",\"url\":\"https:\/\/medicoweb.com\/main\/en\/iris-dr-dddr-iris-d-ddd-iris-vdr-vddr\/\",\"name\":\"Iris DR (DDDR) \u2013 Iris D (DDD) \u2013 Iris VDR (VDDR) - MEDICO S.R.L.\",\"isPartOf\":{\"@id\":\"https:\/\/medicoweb.com\/main\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/medicoweb.com\/main\/en\/iris-dr-dddr-iris-d-ddd-iris-vdr-vddr\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/medicoweb.com\/main\/en\/iris-dr-dddr-iris-d-ddd-iris-vdr-vddr\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/pm_iris_dr_d_vdr.jpg\",\"datePublished\":\"2019-12-02T15:36:09+00:00\",\"dateModified\":\"2020-02-20T08:35:22+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/medicoweb.com\/main\/en\/iris-dr-dddr-iris-d-ddd-iris-vdr-vddr\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/medicoweb.com\/main\/en\/iris-dr-dddr-iris-d-ddd-iris-vdr-vddr\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/medicoweb.com\/main\/en\/iris-dr-dddr-iris-d-ddd-iris-vdr-vddr\/#primaryimage\",\"url\":\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/pm_iris_dr_d_vdr.jpg\",\"contentUrl\":\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/pm_iris_dr_d_vdr.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/medicoweb.com\/main\/en\/iris-dr-dddr-iris-d-ddd-iris-vdr-vddr\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/medicoweb.com\/main\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Iris DR (DDDR) \u2013 Iris D (DDD) \u2013 Iris VDR (VDDR)\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/medicoweb.com\/main\/en\/#website\",\"url\":\"https:\/\/medicoweb.com\/main\/en\/\",\"name\":\"MEDICO S.p.A.\",\"description\":\"Italian Design For Life\",\"publisher\":{\"@id\":\"https:\/\/medicoweb.com\/main\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/medicoweb.com\/main\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/medicoweb.com\/main\/en\/#organization\",\"name\":\"MEDICO S.p.A.\",\"url\":\"https:\/\/medicoweb.com\/main\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/medicoweb.com\/main\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/logo_medico2016-1.png\",\"contentUrl\":\"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/logo_medico2016-1.png\",\"width\":350,\"height\":84,\"caption\":\"MEDICO S.p.A.\"},\"image\":{\"@id\":\"https:\/\/medicoweb.com\/main\/en\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/MedicoSpa\/\",\"https:\/\/it.linkedin.com\/company\/medico-s.p.a.\",\"https:\/\/www.youtube.com\/channel\/UCobmQUF5q8SwwMSZ00fA65g\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Iris DR (DDDR) \u2013 Iris D (DDD) \u2013 Iris VDR (VDDR) - MEDICO S.R.L.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/medicoweb.com\/main\/en\/iris-dr-dddr-iris-d-ddd-iris-vdr-vddr\/","og_locale":"en_US","og_type":"article","og_title":"Iris DR (DDDR) \u2013 Iris D (DDD) \u2013 Iris VDR (VDDR) - MEDICO S.R.L.","og_description":"Iris DR (DDDR) Iris D (DDD) Iris VDR (VDDR) &nbsp; &nbsp; Advanced dual-chamber pacingwith the support of remote control Learn more about: Mobile remote monitoring\u00a0 | Single Lead VDD Pacing Diagnostic evaluation of tachycardia episodes based on an innovative electrogram&hellip;","og_url":"https:\/\/medicoweb.com\/main\/en\/iris-dr-dddr-iris-d-ddd-iris-vdr-vddr\/","og_site_name":"MEDICO S.R.L.","article_publisher":"https:\/\/www.facebook.com\/MedicoSpa\/","article_modified_time":"2020-02-20T08:35:22+00:00","og_image":[{"url":"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/pm_iris_dr_d_vdr.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/medicoweb.com\/main\/en\/iris-dr-dddr-iris-d-ddd-iris-vdr-vddr\/","url":"https:\/\/medicoweb.com\/main\/en\/iris-dr-dddr-iris-d-ddd-iris-vdr-vddr\/","name":"Iris DR (DDDR) \u2013 Iris D (DDD) \u2013 Iris VDR (VDDR) - MEDICO S.R.L.","isPartOf":{"@id":"https:\/\/medicoweb.com\/main\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/medicoweb.com\/main\/en\/iris-dr-dddr-iris-d-ddd-iris-vdr-vddr\/#primaryimage"},"image":{"@id":"https:\/\/medicoweb.com\/main\/en\/iris-dr-dddr-iris-d-ddd-iris-vdr-vddr\/#primaryimage"},"thumbnailUrl":"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/pm_iris_dr_d_vdr.jpg","datePublished":"2019-12-02T15:36:09+00:00","dateModified":"2020-02-20T08:35:22+00:00","breadcrumb":{"@id":"https:\/\/medicoweb.com\/main\/en\/iris-dr-dddr-iris-d-ddd-iris-vdr-vddr\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/medicoweb.com\/main\/en\/iris-dr-dddr-iris-d-ddd-iris-vdr-vddr\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/medicoweb.com\/main\/en\/iris-dr-dddr-iris-d-ddd-iris-vdr-vddr\/#primaryimage","url":"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/pm_iris_dr_d_vdr.jpg","contentUrl":"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/pm_iris_dr_d_vdr.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/medicoweb.com\/main\/en\/iris-dr-dddr-iris-d-ddd-iris-vdr-vddr\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/medicoweb.com\/main\/en\/"},{"@type":"ListItem","position":2,"name":"Iris DR (DDDR) \u2013 Iris D (DDD) \u2013 Iris VDR (VDDR)"}]},{"@type":"WebSite","@id":"https:\/\/medicoweb.com\/main\/en\/#website","url":"https:\/\/medicoweb.com\/main\/en\/","name":"MEDICO S.p.A.","description":"Italian Design For Life","publisher":{"@id":"https:\/\/medicoweb.com\/main\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/medicoweb.com\/main\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/medicoweb.com\/main\/en\/#organization","name":"MEDICO S.p.A.","url":"https:\/\/medicoweb.com\/main\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/medicoweb.com\/main\/en\/#\/schema\/logo\/image\/","url":"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/logo_medico2016-1.png","contentUrl":"https:\/\/medicoweb.com\/main\/wp-content\/uploads\/logo_medico2016-1.png","width":350,"height":84,"caption":"MEDICO S.p.A."},"image":{"@id":"https:\/\/medicoweb.com\/main\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/MedicoSpa\/","https:\/\/it.linkedin.com\/company\/medico-s.p.a.","https:\/\/www.youtube.com\/channel\/UCobmQUF5q8SwwMSZ00fA65g"]}]}},"_links":{"self":[{"href":"https:\/\/medicoweb.com\/main\/en\/wp-json\/wp\/v2\/pages\/5433","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/medicoweb.com\/main\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/medicoweb.com\/main\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/medicoweb.com\/main\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/medicoweb.com\/main\/en\/wp-json\/wp\/v2\/comments?post=5433"}],"version-history":[{"count":1,"href":"https:\/\/medicoweb.com\/main\/en\/wp-json\/wp\/v2\/pages\/5433\/revisions"}],"predecessor-version":[{"id":6583,"href":"https:\/\/medicoweb.com\/main\/en\/wp-json\/wp\/v2\/pages\/5433\/revisions\/6583"}],"wp:attachment":[{"href":"https:\/\/medicoweb.com\/main\/en\/wp-json\/wp\/v2\/media?parent=5433"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}